﻿                      WinRiver II Data Acquisition Software Package
                           Teledyne RD Instruments

-------------------------------------------------------------------------------------
Current Release: 2.26.0.4 (January 2023 )
-------------------------------------------------------------------------------------

Details:  This is the latest version of TRDI's river and coastal data acquisition 
software package where the primary use is for discharge calculation.  Although 
this is its primary function, it can be used for general coastal survey applications. 

--------------------------------------------------------------------------------------
How to Update to Latest Version:  To download the latest version click on the 
download button. Once downloaded double click on the file and the program will install. 

Send all questions to the Customer Service Department.

EMAIL Address: rdifs@teledyne.com
--------------------------------------------------------------------------------------
Version 2.26.0.4 (January 2023 - present)
- Updated Chinese translations
- Minor bug fixes

--------------------------------------------------------------------------------------
Version 2.25.0.3 (April 2022 - January 2023)
- Added support for RiverPro 600 kHz.

--------------------------------------------------------------------------------------
Version 2.24.0.8 (September 2021 - January 2022)
- Updated Chinese translations.
- Added Workhorse II support.
- ISM compass calibration bug fix.
- Fixed countour graph scaling bug.

--------------------------------------------------------------------------------------
Version 2.23 (Sep 2020 - August 2021)
- Fixed an issue where classic ASCII output is output to the wrong file when an 
  unchecked transect is reprocessed.

--------------------------------------------------------------------------------------
Version 2.22 (Mar 2020)

Important:
- This is the required software version for RiverRay/RiverPro/RioPro shipped circa 
  March 2020 or later.

New Features:
- Added QA/QC Component for quick evaluation of Transect quality
- Revised ISM Compass Calibration flow for improved robustness
- Added ability to manually input edge discharge estimates
- Added warning message when starting a transect and a compass calibration has not 
  been performed
- Added display of accumulated mean discharge on the Total Discharge Time Series
- Improved graphics on contour and timeseries displays

Issues addressed:
- Pop up screens no longer cover the measurement window
- "XYZ" Coordinate renamed to "Instrument"
- Added column labels option on generic ASCII output
- Made GPS decoder match all talker-id's (GGA, VTG, DBT, HDT)
- Power Curve Coeff no longer limited to a max value of 0.8
- Fixed GPS data latency issue
- Fixed issues calibrating ISM compass
- Fixed issue where inconsistent Magvars not reporting with '*'
- BT velocities now properly screened in classic ASCII output
- Added total exposure time to F12 Discharge Summary
- Addressed an issue where 'Use 3 beam solution for WT' was not applied unless 'Use 
  3 beam BT' was also used
- Fixed reporting of %BadBottomTrack in Loop MBT
- Fixed an issue where RiverPro would not start pinging
- Fixed an issue on low-resolution monitors where the new Measurement window could 
  not be advanced
- Fixed an issue where the Bins were scaled incorrectly in contour plots
- Fixed an issue where the Serial Number SN in .mmt and in Q Measurement Summary does not 
  match SN in transects or in "Test ADCP"
- When voltage drops below 11 Volts, show in red in Header Tabular
- Added GPS heading to Heading/Pitch/Roll time series plot
- Improved robustness of BlueTooth communications
- Fixed several Chinese/language issues
- Fixed the reporting of bin size for auto-profiling modes
- Fixed a hang/crash when changing references during transect data collection
- Fixed an issue where default directories were not context sensitive

--------------------------------------------------------------------------------------
Version 2.21 (Sep 2019 - Jan 2020)

Issues addressed:
- Fixed issue where Edge Distance popups do not appear when F5 is used.

--------------------------------------------------------------------------------------
Version 2.20 (May 2018 - Sep 2019)

New Features:
- Added Vertical Beam profile data types to contour charts.
- Added ‘Motion’ tabular display for comparison of DMG, Length, and Bad Ensembles
  between BT, GGA, and VTG references.

Issues addressed:
- Fixed 'Apply to all...' for parameters in the "External Heading" and "GPS"
  sections.
- Fixed problem where 'Apply to all...' functionality was not properly saved in the
  mmt file for transects without pre-existing Playback Configuration node.
  NOTE: pre-existing mmts containing this bug will not automatically be fixed. The 
  user must clear the 'Apply to all...' setting, close the Playback Configuration,
  then re-apply the 'Apply to all...' setting, and again close the Playback 
  Configuration to correct the issue.  Transects (or Playback Configurations) added 
  after the 'Apply to all...' functionality is set will NOT inherit that 
  functionality.  

--------------------------------------------------------------------------------------
Version 2.19 (Mar 2018 - present)

New Features:
- Minimum required version for Q-View v2.0.
- Update Stationary Moving Bed Test to handle small/negligible upstream motion.
- Added support for SentinelV-RT systems.

Issues addressed:
- Corrections to the Japanese localization package.
- Improve handling of Microsoft Bluetooth drivers.
- Start and End times in Print Preview Q Measurement Summary are now rounded.
- Q Print Preview: COV is now in percent.

--------------------------------------------------------------------------------------
Version 2.18 (Aug 2016 - Mar 2018)

New Features:
- Added Dynamic Residual Analysis for Transect pass/fail criterion.
- Added a survey/location reference line to the ship track charts.
- Incorporate GPS Antenna position offset from ADCP when determining ADCP Lat/Lon.
- Use transect file name in Generic ASCII out file names.
- Moved application setup and configuration files to Measurements folder for
  improved Windows 7/8/10 security compatibility.
- Display ADCP battery voltage on the Ensemble Header Tabular display.
- When screening depth, screen the vertical beam depth using BT depths.
- Added Heading Offset to Measurement Wizard when using External Heading or
  Integrated EH.
- Added an Acquire Dashboard for enhanced acquire mode feedback.

Issues addressed:
- Corrected usage of the MagVar, External Heading Offset, and Beam 3 Misalignment transect 
  properties.  NOTE:  Reprocessing measurements with non-zero Beam 3 Misalignment values will
  result in changes to the discharge quantities.
- Corrected the generic ASCII output for EH Heading and added an output for ADCP Heading.
- Fixed an issue where the reported number of bins in an ensemble was wrong during
  times of lost ensembles.
- Changed wording in MBT Summary to use 'NOTE' vs. 'FAIL' on transects where the test
  was valid but not recommended to be used due to low moving bed velocity.
- Improved messaging of ISM Compass Cal routines during times when Calibration is
  yielding unusable solutions.
- Fixed a bug when changing starting banks post-measurement using GPS reference.
- Inhibit saving of Q-View intermediate files when Q-View connection is disabled.
- Corrected and extended numerous Chinese language translations.
- Fixed an issue where Mean V (Q/A) was positive when the Q was negative.
- Fixed an issue where Moving Bed analysis was not performing correctly on non-English
  language computers.
- Fixed an issue causing the last edge ensemble to not be included in the discharge 
  reported on the Discharge Summary.

--------------------------------------------------------------------------------------
Version 2.17 (Feb 2016-Aug 2016)
- Added new Composite depth mode that prioritizes slant beam depths over vertical 
  beam depth and made it the default for all new measurements.
- Fixed the saved reference not being used when opening a measurement through the 
  Measurement Control window.
- Fixed an infrequent bug that could cause all the discharge of an ensemble to be 
  marked bad.
- Fixed issues with GPS time stamps that only had 1 digit of resolution for 
  fractional seconds.
- Corrected some Portuguese language translations.

--------------------------------------------------------------------------------------
Version 2.16 (Sep 2015-Feb 2016)

- Fixed a bug during Acquire where River Depth could become unusually large.
- Add support for the RioPro.
- WinRiver now accepts $GPZDA date&time msg with 3 decimal places of precision.
- Add Manual Mode Programming for RiverRay.

--------------------------------------------------------------------------------------
Version 2.15 (Nov 2014-Sep 2015)

- Integrated GPS RiverPro GGA velocity reference now reported correctly
- RiverPro vertical velocity profiling defaults in wizard updated
- Memory leak introduced in v2.14 fixed
- Added checkbox to enable/disable Q-View connection
- Fixed averaging of RiverPro vertical profile data.

--------------------------------------------------------------------------------------
Version 2.14 (Aug 2014-Nov 2014)

- GPS quality indicator of "3" is now accepted.
- Velocity Reference is saved and restored from MMT.
- Running in French: all moving bed test nodes can be used.
- Right clicking on panels always brings up popup choices.
- Moving Bed results now have correct units displayed.
- Added "WinRiver I Sidelobe Calculations" option.
- Fixed a bug where certain data was causing the Contour Chart data slider to disappear.
- Fixed French translation for "%Bad Bins" in Composite Tabular.
- Percent Bad Bins was not calculated correctly when there were lost ensembles.
- Water Dir was not reported as BAD when there is a Lost Ensemble.
- Added support for RiverPro.
- Added "Auto" baud rate setting for RiverPro Integrated GPS.
- User-entered commands are no longer limited to 25 characters.
- Added support for Q-View.
- User can switch between External Heading and ADCP heading when reprocessing data.
- Added button to restore ISM Compass calibration to Factory Default.
- Fixed a bug in the Velocity Profile chart where the Velocity Direction in the tooltip
  was wrong.

--------------------------------------------------------------------------------------
Version 2.13 (Apr 2014-Aug 2014)

- Add Russian translations for ISM compass calibration and Moving Bed processing.

--------------------------------------------------------------------------------------
Version 2.12 (Sep 2013-Apr 2014)

- Add support for River Depth from Vertical Beam in RiverRay systems.
- Classic ASCII Output: Depth sounder depth is now corrected for SoS changes.
- RiverRay systems with internal GPS now show their GPS status in Acquire Control.
- Depth Sounder depth in Generic ASCII out is now corrected depth not raw depth.
- Added the "Composite" river depth source.
- Corrected a compatibility issue between WinH-ADCP and WinRiver II v2.11.

--------------------------------------------------------------------------------------
Version 2.11 (May13-Sep 2013)

- Data files with ensemble size of 641 bytes now decode properly.
- Heading offset is no longer incorrectly scaled from m. to ft.
- Significantly improved Serial Port detection times, especially with Bluetooth
  serial ports.
- Fixed numerous issues with WinRiver locking up when Bluetooth Comms are lost.
- Make Wizards appear with correct size and location for tablets in portrait mode.
- Added the Quick Measurement Wizard (Quick MMT).

--------------------------------------------------------------------------------------
Version 2.10 (Sep12-May13)

- Don't scale WT Velocity or BT Velocity for RiverRay when changing Salinity or
  Speed of Sound.
- Ensure no cells below sidelobe are being used in Moving Bed Correction algorithms.
- Change default for "Mark Bad Below Sidelobe" for RiverRay to True/Checked.
- Fixed ISM Calibration report errors.
- Change default for "Use 3 Beam Solutions For WT" for all instruments to True/Checked.

--------------------------------------------------------------------------------------
Version 2.09 (Aug12-Sep12)

- Documented ASCII out component descriptions.
- RiverRay - Surface bin size and number of bins shown incorrectly.
- Fix RiverRay sidelobe cut-off region and display.
- Fix StreamPro compass calibration status display in the Q Measurement Sum-mary.
- Added PT3 to Self Test Suite for RiverRay.
- Fixed RiverRay Surface Bin Size in Ensemble Tabular not responding to units change.
- Implement Loop Correction and Stationary Moving Bed Analysis.
- Add count of Surface Bins to Ensemble Tabular for RiverRay.
- Fixed Compass Cal failing to proceed in WH with 4GB Memory.
- Improved colors for ISM Compass Cal.
- Display Calibration AND Evaluation status on Q Print Preview.
- Change ISM Compass Cal Report to display 3 digits of precision.
- Improve ISM compass calibration routines/procedures.
- Turn off bin-mapping for RiverRay data.

--------------------------------------------------------------------------------------
Version 2.08 (Dec11-Aug12)

- Section-By-Section support removed.
- Updated default Water Velocity Error thresholds for StreamPro.
- Correctly set the default depth for profile and contour graphs.
- Fixed "zoom to extents" for contour plot.
- Added "Instrument Type" to Q Measurement Summary for RiverRay.
- Updated processing defaults for RiverRay.
- Fixed a bug on Windows 7 where users could not set the clock on StreamPro.
- Added RightEdgeDistance to HYDROML output.
- Fixed a case where Bins above the Sidelobe were being marked BAD on heavily pitched
  RiverRay systems.
- Fixed a case where Beams 3 and 4 were getting marked bad when Beam 1 bottom track
  was bad for RiverRay.
- Fixed a bug where WinRiver was unable to record data with GPS near Greenwich meridian.
- Added ability to set baud rate of internal GPS on RiverRay.
- Fixed Sidelobe calculation for RiverRay and pulse coherent pings.
- Fixed a bug where Classic ASCII out was always outputting backscatter even if
  intensity was selected.
- Fixed a case where some RiverRay data was outputting "1.$" for intensities.
- Fixed a crash with the Backscatter Contour plot of some RiverRay data.
- Updated Copyright notice to 2011.
- Add one digit of precision to depth sounder display.
- Added Language translations: German, Japanese, French, Hungarian, Portuguese, Spanish


--------------------------------------------------------------------------------------
Version 2.07 (Nov09-Dec11)

WinRiver II and Section by Section:
- Fixed missing "Configure" menu item in foreign language versions.
- Improved compatibility with WHv5x.xx

--------------------------------------------------------------------------------------
Version 2.06 (Sep09 - Nov09)

NOTE: In StreamPro Firmware v31.07 the Long Range mode has been extended to 6 meters.
For compatibility with WinRiver II v2.06, existing Long Range StreamPros must have their 
firmware updated to v31.07. This will automatically give you 6 meter range.


WinRiver II:
- Added Compass Compatibility for new StreamPro Firmware
- Added support for enhanced 6m StreamPro Long Range mode
- Fixed "Set Clock" hanging the program on RiverRay
- Fixed sidelobe cutoff line being drawn too shallow for RiverRay in Coherent mode
- Fixed "ADCP Test" Commands to be appropriate for RiverRay
- Fixed WHv5x.xx not being recognized

Section by Section:
- Removed Add/Remove Option since Section by Section option is now stored in Firmware.
- Added Compass Compatibility for new StreamPro Firmware
- Added support for enhanced 6m StreamPro Long Range mode
- Fixed several RiverRay crashing issues

--------------------------------------------------------------------------------------
Version 2.05 (May09 - Sep09)

WinRiver II:
- Fixed incorrect maximum velocity calculation. 
- Added Magnetic Variation correction for water and bottom velocities collected in Earth Coordinates.
- Removed ability to save measurement file to directories other than current measurement directory.
- Fixed problem with depth sounder file not being recorded when depth sounder "Use in Processing" flag was unchecked.
- Added a check to prevent illegal characters in file and folder names.
- Fixed crash when changing line color in Ship Track plot.
- Added Flow Speed to Detailed Discharge Tabular.
- Changed WT Error Velocity Thresholds for StreamPro to depend on predicted standard deviation.
- Fixed Tabular Velocity�s discharge not being marked bad under the averaged bottom when velocities were bad. 
- Fixed problem with ASCII output line 5: starting and ending Q were reversed when starting bank was the Right bank.
- Fixed problem with ASCII output line 2 as it had a wrong sign for boat velocity in GGA/VTG reference.
- Fixed problem with bad commands being generated by the wizard if StreamPro was chosen without being connected.
- Fixed problem with ASCII output: when using �Reference: None� the velocities were still reported as �Reference: BT�.

Section by Section: 
- Fixed problem with the calculation of top discharge for no-slip method (ice measurement).
- Fixed problem with occasional crashing when reading xml nodes. 
- Fixed problem with velocities in the measurement summary being wrong for Ice and Bidirectional methods.
- Fixed problem with saving the measurement file in playback.
- Fixed problem with ADCP depths entered in English units.
- Added a check to prevent illegal characters in file and folder names.
- Fixed problem in acquire with sections occasionally being duplicated.
- Fixed problem with Section Summary when there were no ensembles recorded for the section. 
- Fixed crash when closing section's property during acquire.
- Changed WT Error Velocity Thresholds for StreamPro to depend on predicted standard deviation.
- Fixed problem with bad commands generated by wizard if StreamPro was chosen without being connected.
- Fixed wizard Auto Mode Selection to be the same as in WinRiver II, Moving Boat. 
- Fixed problem with WT Error Velocity not being set for Rio-Grande. It now matches Moving Boat setting. 
--------------------------------------------------------------------------------------

Version 2.04 (Dec08 - Apr09)

WinRiver II:
- Added a flag to the Processing page to turn on/off screening of bottom depths based on 
  bottom velocity.


Section by Section:
- Added a flag to the Processing page to turn on/off screening of bottom depths based on 
  bottom velocity.
--------------------------------------------------------------------------------------

Version 2.03 (Oct08 - Dec08)

WinRiver II:
- Checked compatibility with Vista. 
- Fixed several instability issues.
- Changed computation of the sidelobe. 
- Fixed problem with Discharge profile graph crashing. 
- Enabled RGTest for the StreamPro.
- Added measurement number to the output directory name.
- Modified maximum velocity calculation algorithm.
- Fixed problem with missing ensembles being reported as �Bad� instead of �Lost".
- Changed locking measurement mechanism to be compatible with Unix data storage.
- Added several items to HYDROML schema.
- Fixed problem with QA/QC node timestamps sometimes not being consistent.
- Fixed problem with wrong VTG/GGA north boat velocities in classic ASCII out.
- Added ability to properly view up-looking data.
- Fixed problem with Total Q not including last edge after ending a transect in Composite tabular.
- Added ability to automatically uninstall any prior versions during the installation.
- Fixed problem with loosing raw moving bed data when no delimiter in the file name.
- Fixed problem with filename when generating classic ASCII output for loop data.
- Fixed problem with locking-up in Wizard during setup with certain transducer depths.
- Fixed problem with counting passes in RGTest.
- Changed calculation of the last line in Q measurement summary to be consistent with Discharge 
  summary table.
- Changed default filename prefix from station name to station number.
- Fixed Composite tabular to display data correctly with reference set to None.
- Added calculated "a" coefficient to generic ASCII out.
- Fixed Version field in mmt file.
- Added water column averaged velocity to generic ASCII out.
- Fixed problem in Processing page when small changes to thresholds were not always used/saved 
  when in English units.
- Fixed problem with transect number when creating data from new style *.PD0 files.
- Fixed values in SDev row on Q Measurement summary printout when in English units.
- Fixed ADCP frequency in Q measurement summary.
- Removed a requirement to process transect before printing HYDROML or Q Summary preview.
- Fixed % bad ensembles label on Q Measurement summary.
- Improved behaviour when pressing Ctrl-F5, Shift-F5, or Shift-F6 twice during data review.
- Enabled WM13 selection when StreamPro not connected.
- Fixed problem when attempting to create ASCII out files over network.
- Added software filters and thresholds in Ship coordinates system.
- Fixed label for Width wrong on Q Measurement summary.
- Added limitation for mode 12 for depth cell size not to bigger than 1 meter.
- In mode 12 decreased number of sub-pings in WO-command by one.
- Fixed problem with remarks in Measurement summary sometimes being printed as one long line.
- Added ability to collect more transects after a crash.
- Fixed label for WT Pings on Q Measurement summary.
- Fixed behaviour of Composite tabular when GPS is invalid or lost.
- Fixed some problems when calibrating the compass.
- Fixed problem with discharge in classic ASCII output when changing reference.
- Updated language pack.


Section by Section:
- Added ability to set ADCP depth for each section.
- Added ability to edit section location in playback.
- Fixed problem with printing summary when files are on a network.
- Removed 'StreamPro' from the title in Q measurement summary.
- Disabled selection of Set ADCP clock and other tests while pinging.
- Added new velocity magnitude graph for viewing/evaluating the extrapolation profile for each section.
- Added ability to mark a section not to be used in playback.
- Added ability to use the screening thresholds.
- Added ability to set extrapolation on a per section basis (only ice, bidirectional, normal, wind).
- Improved behaviour when pressing Ctrl + F5 too many times in a raw.
- Fixed some problems when importing files collected with StreamPro software.
- Added ability to reload a .mmt file created earlier and start collecting data.
- Added ability to display portion of a river measured before a crash.
- Updated language pack.
-------------------------------------------------------------------------------------

Version 2.02 (Apr08 - Oct08)
- Added support for Chinese language

WinRiver II:
- Fixed incorrect Absorption coefficient (Processing page) conversion to English units. 
- Removed never used Wizard Summary fields.
- Fixed resolution of elapsed time in classic ASCII Output format. 
- In playback set End Q to zero when in the middle of the river.
- Fixed error message for non-admin users. 
- Fixed flag for Weighted mean depth value when exporting StreamPro xml file.
- Fixed compatibility with old WinRiver for Longitudes less than 100 degrees.
- Fixed ASCII output when reporting bad depth data.
- Fixed default header for depth sounder from "$GPDBT" to "$SDDBT".
- Fixed problem with internal Bluetooth COM port on Dell laptops.

Section by Section:
- Changed rounding of StreamPro maximum depth when in English units.
- Reset section number if pinging stopped.
- Changed logic for StreamPro Mode 13 valid pings calculation to remove error message.
- Changed measurement time to zero for the edges.
- Changed end edge start time to account for the time the previous section lasted.
- Changed measured discharge calculation. 
- Fixed flag for Weighted mean depth value when exporting StreamPro xml file.
- Changed default for EX-command for Rio Grande from earth to ship.

-------------------------------------------------------------------------------------

Version 2.01 (Nov07 - Apr08)

WinRiver II:
- Added better support for Monitor/Sentinel WorkHorse ADCPs. 
- Added support for COM ports bigger than 32. 
- Moved the default position of the Acquire Control display to the lower right corner 
  of the display (over Composite Tabular screen). 
- Added "GPS Delay" parameter to "DS/GPS/EH" page. 
- Fixed broken GPS compatibility with older versions of WinRiver. 
- Fixed problem with GPS lagging behind the ensemble data for high GPS output rates. 
- Fixed problem when printing in landscape. 
- Fixed problem when sub-sectioning file with lost ensembles. 
- Fixed sidelobe screening for intensity and correlation that did not account for 
  transducer offset. 
- Fixed depths numbers in Stick Ship Track when switching units. 
- Fixed problem with updating the units in Stick Ship Track.
- Fixed behavior of the Wizard with StreamPro when running second time. 
- Corrected wording in measurement wizard GPS warning. 
- Mode 12 warning is now shown only when Rio Grande is selected. 
- Fixed problems with incorrect save location after measurement files have been moved.
- Re-arranged items on the "Output Filename Option" page in the wizard.
- Changed the minimum allowed input value for Near Zone Distance to 0.
- Fixed drawing of the line between transects and statistical information when the 
  last transect is not checked.

Section by Section:
- Added capability to reprocess with different section angles than the data was 
  collected. 
- Changed layout of Composite Tabular display.
- Changed behavior after re-processing so the program repositions to ensemble/
  section selected by the user. 
- Fixed problem with calculating mean velocity during acquire after changing IP 
  Distance.
- Fixed problem with discharge not being updated after changing velocity reference. 
- Fixed value of "Distance from IP" in CSV file. 
- Fixed value of "Total_Width" in CSV file when saving file in English units. 
- Fixed problem with "SxS Report" not being updated with some values from Site 
  Information page. 
- Changed resolution of "Correction Factor" on "Section Properties" dialog. 
- Removed "Transect Number" from the wizard. 
- Fixed problem with decoding some values from StreamPro XML file. 
- Changed auto-scaling of "Section Contour" graph so section and ensemble velocity 
  are scaled the same.
- Fixed "Bottom Q" value on section contour graph. 
- On the "Section Properties" dialog added display of the "Edge Shape". 
- Added pre-filling of some Acquire Wizard fields.
- Fixed problem updating Composite Tabular when Flow Type was changed.
- Fixed problem handling poor bi-directional flow type data set. 
- Fixed problem in Section Properties Dialog: Acquisition interval was always 40 sec.
- Fixed problem with bad distance value in "Section Discharge Summary" if section 
  was rejected.

-------------------------------------------------------------------------------------

Version 2.00 (Sept07 - Nov07)
- Added �Section by Section� subprogram.
- Disabled tests in Acquire menu for the StreamPro.
- Disabled �Update Rate� in the wizard for the StreamPro.
- Forced �Bottom Mode� selection to 10 in the wizard for the StreamPro.

-------------------------------------------------------------------------------------

Version 1.03 (Jul07 - Sept07)
- Fixed problem with assigning transect numbers to all �000� when importing old 
  data files.  
- Changed generic ASCII Output format for Longitude and Latitude.
- Fixed problem with saving files that contain '.' in directory path.
- Fixed problem with the discharge profile graph when using constant or 3-pt for 
  the top extrapolation method.
- Fixed problem with finding configuration files when creating measurement from 
  StreamPro data files if filename has extra "."
- Fixed problem with decoding VTG when "mode indicator" field missing.
- Fixed problem with �Stop Pinging� menu item being disabled.
- Fixed fatal exception when dragging Generic ASCII Output item.
- Fixed problem with bad data file crashing the application playback.
- Fixed problem with �Number of Ensembles� decoding in Detailed Discharge tabular 
  display.
- Fixed problem with wrong bin size chosen for certain wizard inputs.
- Changed generic ASCII output Latitude and Longitude resolution.
- Fixed problem with PD0 and mmt files stored in incorrect location.
- Increased resolution of decimal places for Latitude and Longitude on Composite 
  and GPS displays.
- Fixed problem with classic ASCII output combining information from different 
  data files.  
- Added speed of sound correction for bottom track depth.


-------------------------------------------------------------------------------------

Version 1.02 (Apr07 - Jul07)
- Fixed problem with generating ASCII out.
- Fixed problem with beam depths in BT Tabular window. 
- Fixed problem with not consistently saving configurations settings.
- Fixed problem with edge distances while acquiring data. 
- Added resolution to Gage Height values. 
- Added warning in the measurement wizard if the ADCP depth is set to zero. 
- Fixed problem with some StreamPro data in playback. 
- Fixed problem with locking up while using measurement wizard when following 
  specific steps. 
- Added reference to measurement file. 
- Added warning when measurement is locked and closing a measurement. 
- Added warning when measurement is locked and printing measurement summary. 
- Fixed problem with Site Discharge and Playback Configuration icons. 
- Fixed problem with Duration on the Composite Tabular display that was truncated 
  to seconds.
- Changed code for Minimum Profiling Depth for Cell 1 and 2.


-------------------------------------------------------------------------------------
Version 1.01 (Feb07 - Apr07)
- Initial release